Innovative and reliable

With years of experience in manufacturing
page_banner

About the common faults and solutions of 1880 toilet paper rewinding machine

If you open a small toilet paper processing plant, and the 1880 toilet paper rewinding machine is in use, sometimes some failures will inevitably occur.Once a failure occurs, it will definitely bring a lot of inconvenience to the production of the enterprise and affect work efficiency, not to mention the need to invest a considerable amount of money in maintenance costs.For people who are not proficient in papermaking machinery and equipment, it is difficult to maintain machinery.So what should I do if the 1880 toilet paper rewinding machine is broken?Based on many years of after-sales and maintenance experience, Chusun Industrial will tell you the following solutions and techniques:

1:What should I do with the punching knife shredding paper during the production process?
solution:
1.If there is any broken paper, first check whether the blade is too steep.If it is too steep, please adjust its bottom handle so that the bottom blade falls before running.
2.Check the upper blade!

2:the punching is uneven.What should I do if some places are good to play, but some places are not good?
solution:
1.First check whether the adjustment of the punching bottom knife is balanced.If the heights of the two ends are not equal, adjust the control handles at both ends to make the lower end higher until the two ends are balanced.
2.Slowly turn the punching knife shaft so that the blade is upward, and observe whether the blade is even.If there is any unevenness, please use a grinding wheel to slowly polish the depths of the blade, then idlewild for a period of time, and then observe whether the blade is even.If it is not uniform, use the above method to grind it off until the perforation is uniform.

3.What is the reason for not spraying glue after the roll of paper is finished?
solution:
1.If the nozzle does not spray glue, it may be that the adjustment is too small or the nozzle is broken.
2.If the nozzle is normal, readjust the solenoid valve; if not, the solenoid valve is broken and needs to be replaced!

4.What should I do if the paper roll is too loose or too tight?
Solution: The paper roll is too loose. The paper roll is too loose because the pressure on the paper press shaft is too small.Adjusting the atmospheric pressure of the paper roll to increase the pressure can solve this problem, if the paper roll is too tight, the opposite is true.

5.What should I do if the transmission is too tight during rewinding and the base paper breaks or loosens?
solution:
1.If the base paper breaks due to the rewinding speed is too tight or the conveying speed is too slow, please adjust its conveying structure and adjust the pulley to the large end of the active wheel (the small end of the driven wheel).
2.If the base paper is loose, it is caused by the rewinding speed is too slow or the conveying speed is too fast. The adjustment method is the opposite of the above adjustment.

6.What should I do if the base paper is wrinkled when rewinding?
solution:
1.If the base paper is wrinkled during the rewinding process, please first check where the wrinkling starts.If the base paper is wrinkled, flatten it before removing the wrinkles.
2.Check its anti-wrinkle rod to see if there is an imbalance of unequal height at both ends, whether the anti-wrinkle rod is too low, which anti-wrinkle rod the base paper passes through during the conveying process, and whether the anti-wrinkle rod is not bent enough.Please observe carefully to find out the cause of wrinkling, and then adjust the anti-wrinkle rod until there is no wrinkle in the rewinding.

It should be reminded that after the toilet paper rewinding machine is used for a period of time, the equipment must be maintained regularly, so that it can not only extend the service life of the equipment, but also improve the production efficiency of toilet paper processing!

toilet tissue machine (1)
toilet tissue machine
toilet tissue machine (3)
customer visit (1)

Post time: Dec-01-2023